Share:


PANASONIC MUMA012P1S

Item Specifications
Part Number MUMA012P1S
Type Ultra low inertia
Protection class IP65
About Enclosure Except rotating portion of output shaft and leadwire end.
Environmental Conditions For more details, please refer to the instruction manual.
Voltage specifications (V) 200
Rated output (W) 100
Rated current (A (rms)) 1.0
Holding brake without
Mass (kg) 0.50
Oil seal without
Shaft Key-way, center tap
Rated torque (N ⋅ m) 0.32
Momentary Max. peak torque (N ⋅ m) 0.95
Regenerative brake frequency (times/min) Without option :No limit
With option :No limit
Option (External regenerative resistor) Part No. : DV0P2891
About regenerative brake frequency Note) 1. Regenerative brake frequency represents the frequency of the motor's stops from the rated speed with deceleration without load.
⋅ If the load is connected, frequency will be defined as 1/( m + 1 ), where m = ( load moment of inertia ) / ( rotor moment of inertia ).
⋅ When the motor speed exceeds the rated speed, regenerative brake frequency is in inverse proportion to the square of ( running speed / rated speed ).
⋅ Power supply voltage is AC115 V ( at 100 V of the main voltage ). If the supply voltage fluctuates, frequency is in inverse proportion to the square of ( Running supply voltage /115 ) relative to the value in the table.
⋅ When regeneration occurs continuosly such cases as running speed frequently changes or vertical feeding, consult us or a dealer.
Note) 2. If the effective torque is within the rated torque, there is no limit in regenerative brake.
Rated rotational speed (r/min) 3000
Rated rotational Max. speed (r/min) 5000
Moment of inertia of rotor ( x10-4 kg ⋅ m²) 0.032
Recommended moment of inertia ratio of the load and the rotor 30 times or less
About recommended moment of inertia ratio of the load and the rotor Note) 3. Consult us or a dealer if the load moment of inertia exceeds the specified value.
Rotary encoder: specifications 2500 P/r Incremental
Rotary encoder: Resolution 10000
 

Permissible load

Item Specifications
During assembly: Radial load P-direction (N) 147
During assembly: Thrust load A-direction (N) 88
During assembly: Thrust load B-direction (N) 117
During operation: Radial load P-direction (N) 68
During operation: Thrust load A, B-direction (N) 58


 Inquiry - PANASONIC MUMA012P1S