Share:


SJ-F036

Model

SJ-F036

Type

Static elimination blower

Voltage application method

Variable DC

Applied voltage

±7000 V max.

Ion balance control method

I.C.C. method

Ion balance

±10 V*1

Static elimination time

Approx 0.7 sec.*1

Maximum wind speed

3.5 m/s*2

Maximum air volume

3.1 m3/min.

Ozone density

0.005 ppm max.

Control input

Input

NPN open-collector or non-voltage contact signal

Control output

Alarm output

NPN open-collector, 100 mA max. (40 V max.)

Ion level alert output

Condition alert output

Rating

Power voltage

24 VDC ±10 %

Current consumption

1.2 A or less

Environmental resistance

Ambient temperature

0 to +50 °C

Relative humidity

35 to 65 % RH (No condensation)